This is a great video. Learn more about our Chicago expansion campus.

CHI02 EXPANSION

24

MEGAWATTS

202,000

SQUARE FEET

Capacity

Total Capacity

  • 24 MW

Facility Size

  • 202,000 sq. ft.

Deployments

  • READY STACK™: RackReady ® data halls
  • POWER STACK™: Immediately available shell capacity

Cooling & Efficiency

Cooling

  • N+1 Air cooled chillers with integral free-cooling
  • N+4 Fan walls per data halls

Efficiency

  • Integral free-cooling with each chiller line up
  • PUE 1.3 or better

Cooling Reserve

  • Thermal storage with continuous cooling (future)

Density

  • 7-8 kW/rack
  • 250-300 w/sf
  • High density deployments supported—in excess of 25 kW per cabinet

Safety & Security

Security

  • Perimeter fencing
  • Dual-factor biometric authentication
  • CCTV with 93-day retention

Fire Detection

  • VESDA

Fire Suppression

  • Double interlock pre-action fire suppression system

Certifications & Compliance Supported

  • LEED Silver certification
  • HIPAA/HITECH
  • PCI/DSS
  • AICPA SOC
  • ISO 27001
  • TIER III DESIGN

Power & Reliability

Utility Service

  • Diverse underground utility feeds

Generators

  • N+1 Block Redundant

Fuel Storage

  • Minimum 24 hours of operation

UPS

  • N+1 UPS configuration

PDU

  • N+1 PDU configuration

BMS Controls

  • Client access to BMS portal

Building Hardening

  • Precast concrete structure

Sustainability

  • 100% renewable options available

Diverse Utility and Power Sources

  • Served by ComEd Smart Grid Substations
  • Priority 1 Substation also serves O’Hare International Airport

Connectivity

Diversity

  • 2 Meet-Me-Rooms
  • 3 Diverse entrances

Carrier Availability

  • 7 Carriers on campus
  • Carrier neutral

Additional Connectivity

  • Roof space available

Amenities

Work Space

  • Conference rooms & break rooms
  • Complimentary Wi-Fi
  • Dedicated office space

Storage

  • Shared and private storage/staging

Client Conveniences

  • Showers
  • Bicycle storage
  • EV charging

chi01 data center

13

MEGAWATTS

221,000

SQUARE FEET

Capacity

Facility Size

  • 221,000 sq. ft.

Total Capacity

  • 13 MW critical capacity

Deployments

  • POWER STACK™: Immediately available shell capacity
  • READY STACK™: RackReady ® data halls

Cooling & Efficiency

Cooling

  • N+1 CRAC units with free cooling

Efficiency

  • Pumped refrigerant economization

Density

  • High density deployments supported in excess of 25 kW per cabinet

Safety & Security

Security

  • Dual-factor biometric access
  • CCTV coverage with 93-day retention
  • Secure vehicle gates with badge access
  • Perimeter fencing

Fire Detection

  • Dual smoke detection including VESDA

Fire Suppression

  • Dual-interlock pre-action sprinkler system

Certifications & Compliance Supported

  • Uptime M&O certification
  • LEED Silver certification
  • HIPAA/HITECH
  • PCI/DSS
  • SSAE 18
  • ISO 27001

Power & Reliability

Utility Service

  • Diverse and redundant utility feeds

Generators

  • N+1 redundancy

Fuel Storage

  • Minimum 36 hours of operation

UPS

  • N+1 UPS configuration

PDU

  • 2N PDU distribution

BMS Controls

  • Client access to BMS portal

Building Hardening

  • 190 mph wind-rated structure (EF4)

Flood Plain

  • Above 500-year flood plain

Connectivity

Diversity

  • 2 Meet-Me-Rooms with diverse fiber entrances

Carrier Availability

  • 6 carriers
  • Carrier neutral

Additional Connectivity

  • Roof space available

Amenities

Work Space

  • Conference and break rooms
  • Complimentary WiFi
  • Shared and dedicated office space

Storage

  • Shared and private storage/staging

Client Conveniences

  • Showers
  • Bicycle storage
  • Multi-bay secure loading dock

to get more information or schedule a tour