Zurich
The largest city in Switzerland with a population of over 1.4 million people in its agglomeration, Zurich has an annual gross domestic product that comprises more than 20% of the country’s GDP. Its strong economic stability and privacy laws make Zurich perfect for hyperscalers and large enterprises in search of land and power in a constrained data center market.
ZUR01A
ZUR02
ZUR01A
ZUR01A
A hyperscale-specific design and the only data center in Switzerland powered by separate power generating sources, ZUR01A delivers hyper-redundancy from grid to data hall. The facility is unique in Switzerland in its ability to provide four data hall configurations, in terms of power and size, to allow hyperscalers and cloud providers to deploy their standardized densities and layouts.
COMPLIANCE
- ISO 9001
- ISO 14001
- ISO 27001
- ISO 45001
- ISO 50001
- ISAE 3402
- PCI/DSS Compliant
TOTAL CAPACITY
10 MW IT LOAD
FACILITY SIZE
4,600 SQM WHITE SPACE
Deployments
POWERSTACK™: Immediately available shell capacity
WORK SPACE
Conference rooms and break rooms
WiFi
Complimentary WiFi
Office
Shared and dedicated office space
Storage
Shared and private storage
CLIENT CONVENIENCES
On-site showers, cafeteria
Bike Storage
Yes
Parking
On-site parking & EV charging
Staging area
Yes
Generators
13 Gen – 2250 kVA each
Electrical redundancy UPS
3 out of 4 distributed redundant power systems
16 No. UPS
Each UPS circa 1MVA
5 x 200kW modules
Utilities
Dual power feed 20 MVA
Fuel Storage
N+1 circuits, pumps, tanks (daily, main) with 48 hours of autonomy
Mechanical
IACs for Data Hall cooling: N+1
Density
2.5 kW/sqm
BMS Controls
Yes
Hardened Exterior
Exterior walls steel reinforced poured concrete; ground pilings
Flood Plain
Above 100 year flooding area
Cooling
IACs for Data Hall cooling: N+1 – Hot Aisle Containment
Chiller
Cooling equipment with compressors, free-cooling and aero-adiabatic for ancillary
Water Storage
480 cubic meters
Electrical
UPS Distributed redundancy (4 to make 3) – XYZ for Telco requirements. UPS efficiency > 96%
Free Cooling
Yes – In operation when T° is < 15°C
Diversity
2 Meet-Me-Rooms with 2 fiber entrances
Carrier Availability
Carrier neutral facility
Cloud Access
Available on request
Roof Space
Available
Access
Secure vehicle & pedestrian gates with proximity badge reader
Loading Dock
2 secured Loading Docks
Fencing
Secure perimeter fencing + radar detection around the building
Security
Dual factor authentication – biometric access
Roof
Available for satellite dish
Detection
Vesda
Suppression
Sprinkler system (DH, loading and storage)
ZUR02
ZUR02
With 50MW diverse feeds and permitting approved, the ZUR02 campus is the only major capacity available to support the growth of cloud in Switzerland. It is ideally located to provide expansion capacity in a country where securing land and power is challenging, and can provide a competitive edge to either cloud providers or other large deployments that are facing capacity restraints in the region.
Solutions
TOTAL CAPACITY
36 MW IT LOAD
FACILITY SIZE
12,000 SQM (12x1k SQM) WHITE SPACE
Deployments
HYPERSTACK™: Build-to-Suit
WORK SPACE
Conference rooms and break rooms
WiFi
Complimentary WiFi
Office
Shared and dedicated office space
Storage
Shared and private storage
CLIENT CONVENIENCES
On-site showers, cafeteria
Bike Storage
Yes
Parking
On-site parking & EV charging
Staging area
Yes
Generators
21 Generators x 3.6 MVA
N+1 Configuration
Electrical redundancy UPS
Isolated redundant configuration
6 primary critical system from a dedicated 2.4MW double-conversion static UPS with 5 minutes lithium-ion battery autonomy
1 reserve critical system can support the load of any single PCS under failure or maintenance conditions
Utilities
Dual utility incoming supplies
Fuel Storage
Fuel storage will be provided with 48 hours autonomy, through a combination of bulk and day tank fuel storage
Mechanical
N+1 Critical cooling Installation, hybrid heat rejection units and Air-Cooled Chillers for trim cooling
Density
2.5 kW/SQM
BMS Controls
Yes
Hardened Exterior
Concrete construction
Flood Plain
The site is not in a flood hazard area
Cooling
3 No. primary cooling circuits, each consisting of 7 No. hybrid adiabatic/dry air-cooling systems
Chiller
Air-Cooled Chillers will comprise multiple turbo core compressors
Water Storage
Thermal storage as part of the primary chilled water infrastructure
Electrical
UPS efficiency > 96%
Roof Space
Available for Satellite dish
Access
Secure vehicle & pedestrian gates with proximity badge reader
Loading Dock
2 secured Loading Docks
Fencing
Secure perimeter fencing + radar detection around the building
Security
Dual factor authentication – biometric access
Roof
Available for Photovoltaic pannels (1700 SQM) + Satellite dish
Detection
Multifunction smoke detection and VESDA
Suppression
Pre-action double interlock water mist / sprinkler