OSL01


OSL01


STACK OSL01 data center is a high security colocation center with leading connectivity and central location.

Providing more than 5,100m² of white technical space for primarily READYSTACK solutions, the data center has a rich ecosystem, including 25+ carriers and several direct connects, including Microsoft Azure and Amazon Web Services (AWS).

COMPLIANCE
  • ISO 9001:2015 Quality Management
  • ISO 14001:2015 Quality Management Environmental
  • ISO 27001:2013 Information Security Management System
  • ISO 45001:2018 Occupational Health & Safety Management
  • PCI/DSS
  • LOS Energy Norway 100% Renewable Energy Guarantee
  • ISAE 3402 / SOC 1 Report
Solutions
  • READYSTACK™: Commissioned capacity
2 Million +
5,100 sqm
power
6.8 MW
CAPACITY
POWER & RELIABILITY
COOLING & EFFICIENCY
CONNECTIVITY
SAFETY & SECURITY
Total Capacity

6.8MW

Facility Size

5,100 sqm

Deployments

READYSTACK™: Commissioned capacity

Work Space

Complimentary WiFi
Office space available on request

Storage

Limited storage/staging

 

Client Conveniences

Bicycle storage
Multi-bay secure loading dock

Generators

N+1, 2N redundancy

Fuel Storage

Minimum 24 hours of fuel operation

UPS

N+1 UPS configuration

PDU

2N PDU distribution

BMS Controls

Client access to BMS portal

Cooling

Primary cooling provided by chilled water systems in combination with mechanical cooling systems
Heat export to district heating
N+4 AHUs

Density

High density deployments supported in excess of 1.5 kW per sqm

Diversity

3 Meet-Me-Rooms with diverse fiber entrances

Carrier Availability

25+ carriers
Dark fiber available

Additional Connectivity

Carrer neutral

Security

High grade 360′ boundary fencing with security access control
24 x 7 on-site security personnel
Mantrap intruder detection and card access system
Secure vehicle gates with badge access

Fire Protection

Argonite fire suppression system
High-grade early smoke detection apparatus in conditioned modules

OSL02


OSL02


STACK OSL02 colocation data center is located at the Rosenholm Business Center campus. The entire campus has been constructed to the highest environmental quality standards.

The data center currently provides more than 2,100m² of white technical space for READYSTACK and POWERSTACK solutions, all within reinforced concrete bunkers, providing more than 3m clear floor to ceiling headroom. The data halls have been entirely rebuilt with new mechanical and electrical infrastructures which provide modern, high power data center services.

COMPLIANCE
  • ISO 9001:2015 Quality Management
  • ISO 14001:2015 Quality Management Environmental
  • ISO 27001:2013 Information Security Management System
  • ISO 45001:2018 Occupational Health & Safety Management
  • PCI/DSS
  • LOS Energy Norway 100% Renewable Energy Guarantee
  • ISAE 3402 / SOC 1 Report
2 Million +
2,155 sqm
power
3.8 MW
CAPACITY
POWER & RELIABILITY
COOLING & EFFICIENCY
CONNECTIVITY
SAFETY & SECURITY
Total Capacity

3.8MW

Facility Size

2,155 sqm

Deployments

READYSTACK™: Commissioned capacity

POWERSTACK™: Immediately available shell capacity

Work Space

Conference and break rooms and cafeteria available in the campus
Complimentary campus WiFi
Office space available within the campus

Storage

Shared and private storage/staging

Client Conveniences

Bicycle storage
Secure loading dock

Generators

N+1 redundancy

Fuel Storage

Minimum 24 hours of fuel operation

UPS

N+1 UPS configuration

PDU

2N PDU distribution

BMS Controls

Client access to BMS portal

Cooling

Conditioned modules mechanically cooled by dual coil DX compressors with ‘free’ cooling in CCU with heat rejection to dual cooling water circuits and external adiabatic dry coolers.
Waste heat during winter months used to heat the campus

Density

Average 3kW per sqm

Diversity

2 Meet-Me-Rooms with diverse fiber entrances

Carrier Availability

4 carriers

Dark fiber available

Additional Connectivity

Carrier neutral

Security

24/7 surveillance
Internal and external advanced security surveillance camera system
Card access systems throughout
Campus based zone within zone access control
Secure parking

Fire Protection

Inergen or Novac fire suppression system in conditioned modules
High grade very early smoke detection apparatus in conditioned modules
Monitored automatic smoke detection throughout

OSL03 Campus

  • OSL03A
  • OSL03B
  • OSL03C
  • OSLL1
  • OSLL3

OSL03 Campus

  • OSL03A
  • OSL03B
  • OSL03C
  • OSLL1
  • OSLL3

STACK OSL03 campus is close to Olso city and high capacity, offering good short and long-term scaling opportunities with 100MW available at various stages of development.

2 Million +
56,000 sqm
power
45+ MW
CAPACITY
Campus Capacity

45+MW

Campus Size

56,000 sqm

OSL03A

  • OSL03A
  • OSL03B
  • OSL03C
  • OSLL1
  • OSLL3

OSL03A

  • OSL03A
  • OSL03B
  • OSL03C
  • OSLL1
  • OSLL3

STACK OSL03A is a very efficient colocation data center on our Fetsund Campus, with a strong financial ecosystem and hosts both MSP and hyperscale clients.

The data center follows our modular design principles for scalability and efficiency, and provides 4,200m² of dedicated IT housing space. The campus currently features three operational data centers, with OSL03A being the first to go live.

COMPLIANCE
  • ISO 9001:2015 Quality Management
  • ISO 14001:2015 Quality Management Environmental
  • ISO 27001:2013 Information Security Management System
  • ISO 45001:2018 Occupational Health & Safety Management
  • PCI/DSS
  • LOS Energy Norway 100% Renewable Energy Guarantee
  • ISAE 3402 / SOC 1 Report
2 Million +
4,200 sqm
power
9.8 MVA
Increasable to 12.6MVA
CAPACITY & AMENITIES
POWER & RELIABILITY
COOLING & EFFICIENCY
CONNECTIVITY
SAFETY & SECURITY
Total Capacity

9MW

Facility Size

4,200 sqm

Deployments

POWERSTACK™: Immediately available shell capacity

HYPERSTACK™: Campus & Build-to-suit

Work Space

Complimentary WiFi
Office space available on request

Storage

Shared and private storage/staging

Client Conveniences

Multi-bay secure loading dock

Generators

N+1, 2N redundancy

Fuel Storage

Minimum 48 hours of fuel operation

UPS

N+1 UPS configuration

PDU

2N PDU distribution

BMS Controls

Client access to BMS portal

Flood Plain

Above 1000-year flood plain

Cooling

Indirect evaporative cooling
Adiabatic

Storage

Multiple make-up water sources
Rain water harvesting
12 hours of condenser water storage at full load

Density

High density deployments supported in excess of 2kW/ sqm

Diversity

2 Meet-Me-Rooms with diverse fiber entrances

Carrier Availability

Carrier neutral
Dark fiber available

Additional Connectivity

Roof space available

Security

24/7 Technical shift presence in building
On site 24/7 manned security presence
Internal and external advanced security surveillance camera systems
Man trap, intruder detection and card access systems throughout
High grade boundary fencing, plus vehicle trap and pedestrian access point
Car parking external to security fence
Layered security measures

Fire Protection

Hypoxic fire prevention or optional NOVEC gas release systems
High grade very early smoke detection apparatus in data halls
Monitored automatic smoke detection throughout

OSL03B

  • OSL03A
  • OSL03B
  • OSL03C
  • OSLL1
  • OSLL3

OSL03B

  • OSL03A
  • OSL03B
  • OSL03C
  • OSLL1
  • OSLL3

STACK OSL03B follows our modular design principles for scalability and efficiency and provides 881 sqm of dedicated IT housing space. It is the third operational data center at our Fetsund campus.

The facility is certified to ISO Class 8 filtration for fresh air AHU, together with a unique snow melt system and rainwater re-use for cooling systems. This highly efficient system is uniquely suited to the Nordic climate, yielding efficiencies and cost savings up to 25% beyond the industry average.

COMPLIANCE
  • ISO 9001:2015 Quality Management
  • ISO 14001:2015 Quality Management Environmental
  • ISO 27001:2013 Information Security Management System
  • ISO 45001:2018 Occupational Health & Safety Management
  • PCI/DSS
  • LOS Energy Norway 100% Renewable Energy Guarantee
  • ISAE 3402 / SOC 1 Report
2 Million +
881 sqm
power
3 MW
CAPACITY & AMENITIES
POWER & RELIABILITY
COOLING & EFFICIENCY
CONNECTIVITY
SAFETY & SECURITY
Total Capacity

3MW

Facility Size

881 sqm

Deployments

HYPERSTACK™: Campus & Build-to-suit

Work Space

Complimentary WiFi
Office space available on request

Storage

Shared and private storage/staging

Client Conveniences

Multi-bay secure loading dock

Generators

2N redundancy

Fuel Storage

Minimum 48 hours of fuel operation

UPS

N+1 UPS configuration

PDU

2N PDU distribution

BMS Controls

Client access to BMS portal

Flood Plain

Above 1000-year flood plain

Cooling

Indirect evaporative cooling
Adiabatic

Storage

Multiple make-up water sources including rain water harvesting & snow melt system
72 hours of condenser water storage at full load

Density

High density deployments supported in excess of 3kW/ sqm

Diversity

2 Meet-Me-Rooms with diverse fiber entrances

Carrier Availability

Carrier neutral

Dark fiber available

Additional Connectivity

Roof space available

Security

24/7 Technical shift presence in building
On site 24/7 manned security presence
Internal and external advanced security surveillance camera systems
Man trap, intruder detection and card access systems throughout
High grade boundary fencing, plus vehicle trap and pedestrian access point
Car parking external to security fence
Layered security measures

Fire Protection

NOVEC gas release systems
High grade very early smoke detection apparatus in data halls and power pods
Monitored automatic smoke detection throughout

OSL03C

  • OSL03A
  • OSL03B
  • OSL03C
  • OSLL1
  • OSLL3

OSL03C

  • OSL03A
  • OSL03B
  • OSL03C
  • OSLL1
  • OSLL3

STACK OSL03C is a dedicated and very efficient HYPERSTACK data center on our Fetsund campus. Opened in the fall of 2020, this new, state-of-the-art, environmentally friendly facility follows our modular design principle, for an IT density of 3.22 kW/sqm.

The data center is powered with 100% renewable hydro energy, and certified to ISO Class 8 for fresh air AHU that serves the data hall.

COMPLIANCE
  • ISO 9001:2015 Quality Management
  • ISO 14001:2015 Quality Management Environmental
  • ISO 27001:2013 Information Security Management System
  • ISO 45001:2018 Occupational Health & Safety Management
  • PCI/DSS
  • LOS Energy Norway 100% Renewable Energy Guarantee
  • ISAE 3402 / SOC 1 Report
2 Million +
881 sqm
power
3 MW
CAPACITY & AMENITIES
POWER & RELIABILITY
COOLING & EFFICIENCY
CONNECTIVITY
SAFETY & SECURITY
Total Capacity

3MW

Facility Size

881 sqm

Deployments

HYPERSTACK™: Campus & Build-to-suit

Work Space

Complimentary WiFi
Office space available on request

Storage

Shared and private storage/staging

Client Conveniences

Multi-bay secure loading dock

Generators

2N redundancy

Fuel Storage

Minimum 48 hours of fuel operation

UPS

N+1 UPS configuration

PDU

2N PDU distribution

BMS Controls

Client access to BMS portal

Flood Plain

Above 1000-year flood plain

Cooling

Indirect evaporative cooling
Adiabatic

Storage

Multiple make-up water sources including rain water harvesting & snow melt system
72 hours of condenser water storage at full load

Density

High density deployments supported in excess of 3kW/ sqm

Diversity

2 Meet-Me-Rooms with diverse fiber entrances

Carrier Availability

Carrier neutral

Dark fiber available

Additional Connectivity

Roof space available

Security

24/7 Technical shift presence in building
On site 24/7 manned security presence
Internal and external advanced security surveillance camera systems
Man trap, intruder detection and card access systems throughout
High grade boundary fencing, plus vehicle trap and pedestrian access point
Car parking external to security fence
Layered security measures

Fire Protection

NOVEC gas release systems
High grade very early smoke detection apparatus in data halls and power pods
Monitored automatic smoke detection throughout

OSLL1

  • OSL03A
  • OSL03B
  • OSL03C
  • OSLL1
  • OSLL3

OSLL1

  • OSL03A
  • OSL03B
  • OSL03C
  • OSLL1
  • OSLL3

Adjacent to our operational data centers (OSL03A, B, and C), the Fetsund campus offers additional greenfield land of 18,000 sqm for planning of two further buildings with 3MW each.

All facilities on the STACK Fetsund campus are powered by 100% certified renewable energy.

OSLL3

  • OSL03A
  • OSL03B
  • OSL03C
  • OSLL1
  • OSLL3

OSLL3

  • OSL03A
  • OSL03B
  • OSL03C
  • OSLL1
  • OSLL3

To allow for growth at this popular location, OSLL3 provides an additional 24,000m² of greenfield land, with planning for two buildings of 4MW each.

STACK Fetsund campus has sufficient scope for a total of seven data centers and a capacity of 45MW+.

OSL04 Campus

  • OSL04B
  • OSL04C
  • OSLL2 & L5

OSL04 Campus

  • OSL04B
  • OSL04C
  • OSLL2 & L5

STACK OSL04 Campus is close to the city of Oslo, offering good short and long-term scaling opportunities with 100MW available at various stages of development. The campus is planned for a total of six data centers of 6MW each.

 

 

2 Million +
3,000 sqm
power
6 MW
CAPACITY
Current Capacity

6MW

Expansion Capacity

100MW

Current Facility Size

3,000 sqm

Future Facility Size

69,000 sqm

OSL04B

  • OSL04B
  • OSL04C
  • OSLL2 & L5

OSL04B

  • OSL04B
  • OSL04C
  • OSLL2 & L5

STACK OSL04B is a very efficient HYPERSTACK data center and the first facility on our Holtskogen Campus. It is powered by 100% certified renewable energy and provides more than 3,000 sqm of IT housing space.

Holtskogen is certified to ISO Class 8 filtration for fresh air AHUs that serve the data halls, together with a unique snow melt system and rainwater re-use for cooling systems. This highly efficient system is uniquely suited to the Nordic climate.

COMPLIANCE
  • ISO 9001:2015 Quality Management
  • ISO 14001:2015 Quality Management Environmental
  • ISO 27001:2013 Information Security Management System
  • ISO 45001:2018 Occupational Health & Safety Management
  • PCI/DSS
  • LOS Energy Norway 100% Renewable Energy Guarantee
  • ISAE 3402 / SOC 1 Report
2 Million +
3,000
power
6 MW
CAPACITY & AMENITIES
POWER & RELIABILITY
COOLING & EFFICIENCY
CONNECTIVITY
SAFETY & SECURITY
Total Capacity

6MW

Facility Size

3,000sqm

Deployments

POWERSTACK™: Immediately available shell capacity

HYPERSTACK™: Campus & Build-to-suit

Work Space

Meeting and break rooms
Complimentary WiFi
Office space available

Storage

Shared and private storage/staging

Client Conveniences

Bicycle storage

Multi-bay secure loading dock

Generators

2N redundancy

Fuel Storage

Minimum 24 hours of fuel operation

UPS

N+1 UPS configuration

PDU

2N PDU distribution

BMS Controls

Client access to BMS portal

Flood Plain

Above 1000-year flood plain

Cooling

N+1 resilience for IEC cooling supported by 2N essential power
Indirect evaporative coolers
Waste heat reclamation
Unique snow melt system and rain water reuse for cooling systems
ISO Class 8 filtration for fresh air AHU’s that serve the data halls

Storage

200 m³ for cooling process

Density

3kW/m2

Carrier Availability

Carrier neutral
Dark fiber available

Security

On site 24/7 manned security presence
Security operates from internal monitoring office
Internal and external advanced security surveillance camera systems
Man trap intruder detection and card access systems throughout
High grade boundary fencing compliant with EN1722
Car trap controlled gates
Multi layered security

Fire Protection

Novec fire suppression system throughout
High grade very early smoke detection apparatus in conditioned power modules and the data halls
Monitored automatic smoke detection throughout
Nozzles with silencers

OSL04C

  • OSL04B
  • OSL04C
  • OSLL2 & L5

OSL04C

  • OSL04B
  • OSL04C
  • OSLL2 & L5

STACK OSL04C data center is currently under construction and will comprise two halls, each of 930 sqm dedicated white space.

OSL04C will be the second facility at our Holtskogen campus and, when complete, will be a very efficient, sustainable data center, offering both POWERSTACK and HYPERSTACK solutions.

CAPACITY
Total Capacity

6MW

Facility Size

3,000 sqm

Deployments

POWERSTACK™: Immediately available shell capacity

HYPERSTACK™: Campus & Build-to-suit

OSLL2 & L5

  • OSL04B
  • OSL04C
  • OSLL2 & L5

OSLL2 & L5

  • OSL04B
  • OSL04C
  • OSLL2 & L5

To allow for growth, OSLL2 and L5 offer 69,000 sqm of greenfield land adjacent to the operational facility, OSL04B.

 

CAPACITY
Total Campus Capacity

24MW

Campus Size

40,000 sqm with option for additional 23,000 sqm

Deployments

POWERSTACK™: Immediately available shell capacity

HYPERSTACK™: Campus & Build-to-suit

OSLL4


OSLL4


STACK Ringerike campus lies in the wider Oslo area and offers 29,500 sqm of greenfield land available for HYPERSTACK and POWERSTACK data centers.

The campus will offer very good short and long-term scaling opportunities with line-of-sight to 200MW capacity. The campus has masterplans and DC zoning in place, and permitting for five data centers of 4MW to start.

CAPACITY
Total Campus Capacity

200MW

Campus Size

29,500 sqm

Deployments

POWERSTACK™: Immediately available shell capacity

HYPERSTACK™: Campus & Build-to-suit